3,421 research outputs found

    Coupling between gamma-band power and cerebral blood volume during recurrent acute neocortical seizures

    Get PDF
    Characterization of neural and hemodynamic biomarkers of epileptic activity that can be measured using non-invasive techniques is fundamental to the accurate identification of the epileptogenic zone (EZ) in the clinical setting. Recently, oscillations at gamma-band frequencies and above (>30 Hz) have been suggested to provide valuable localizing information of the EZ and track cortical activation associated with epileptogenic processes. Although a tight coupling between gamma-band activity and hemodynamic-based signals has been consistently demonstrated in non-pathological conditions, very little is known about whether such a relationship is maintained in epilepsy and the laminar etiology of these signals. Confirmation of this relationship may elucidate the underpinnings of perfusion-based signals in epilepsy and the potential value of localizing the EZ using hemodynamic correlates of pathological rhythms. Here, we use concurrent multi-depth electrophysiology and 2-dimensional optical imaging spectroscopy to examine the coupling between multi-band neural activity and cerebral blood volume (CBV) during recurrent acute focal neocortical seizures in the urethane-anesthetized rat. We show a powerful correlation between gamma-band power (25-90 Hz) and CBV across cortical laminae, in particular layer 5, and a close association between gamma measures and multi-unit activity (MUA). Our findings provide insights into the laminar electrophysiological basis of perfusion-based imaging signals in the epileptic state and may have implications for further research using non-invasive multi-modal techniques to localize epileptogenic tissue

    Symmetry-related transitions in the spectrum of nanosized Cubic Y2O3: Tb3+

    Get PDF
    Herein the preparation and cathodoluminescence of nanoparticles of cubic Y2O3:Tb3+ having Tb3+ concentration varying between 0.1 and 10 Mol% are described. The cathodoluminescence spectra were recorded with a high resolution spectrometer, which enabled the identification of Tb3+ lines with C2 and S6 symmetry: the lines at 542.8 nm and 544.4 nm were designated as 5D4→7F5 (C2) and 5D4→7F5 (S6) respectively. The critical distance for energy transfer from Tb3+ ions at S6 lattice sites to Tb3+ ions at C2 lattice sites was found to be >1.7 nm. At the greater distances which prevail at low Tb3+ concentration, this energy transfer virtually stops. From cathodoluminescence spectra recorded in a scanning transmission electron microscope it was concluded that this energy transfer also did not take place if the temperature was reduced below 102 K. The efficiency of the cathodoluminescence of 1% Y2O3:Tb3+ was 6 lm/w at a beam voltage of 15 kV. The decay time of the 5D4→7F5 (C2) transition was substantially shorter than that of the 5D4→7F5 (S6) transition at low Tb3+ concentrations. The decay behavior of the cathodoluminescence images in a field emission scanning electron microscope has been explained in terms of phosphor saturation.We are grateful to the EPSRC and the Technology Strategy Board (TSB) for funding the PURPOSE (TP11/MFE/6/I/AA129F; EPSRCTS/G000271/1) and CONVERTED (JeS no. TS/1003053/1) programs. We are also grateful to the TSB for funding the CONVERT program

    Symmetry-related transitions in the photoluminescence and cathodoluminescence spectra of nanosized cubic Y2O3:Tb3+

    Get PDF
    Herein the photoluminescence spectra of nanosized cubic Y2O3:Tb3+ having Tb3+ concentrations varying between 0.1 and 10 Mol% are described. Low temperature cathodoluminescence spectra from these materials recorded in a scanning transmission electron microscope are presented and discussed. By studying the photoluminescence-spectra recorded at room temperature and focused on the 5D4→7F5 (C2) and 5D4→7F5 (C3i) transitions, at 542.8 and 544.4 nm respectively, it was found that the critical distance for energy transfer from Tb3+ ions at C3i lattice sites to Tb3+ ions at C2 lattice sites was 1.7 nm; at distances >1.7 nm, which prevail at low Tb3+ concentration, this energy transfer virtually stops. The gradual change of the excitation spectra upon increasing the Tb3+ concentration is also explained in terms of energy transfer from Tb3+ at C3i sites to Tb3+ at C2 sites. Cathodoluminescence spectra recorded at low temperatures with the scanning transmission electron microscope provided additional evidence for this radiationless energy transfer.We are grateful to the EPSRC and the Technology Strategy Board (TSB) for funding the PURPOSE (TP11/MFE/6/I/AA129F; EPSRCTS/G000271/1) and CONVERTED (JeS no. TS/1003053/1) programs. The TSB funded the CONVERT program

    Is telomere length socially patterned? Evidence from the West of Scotland Twenty-07 study

    Get PDF
    Lower socioeconomic status (SES) is strongly associated with an increased risk of morbidity and premature mortality, but it is not known if the same is true for telomere length, a marker often used to assess biological ageing. The West of Scotland Twenty-07 Study was used to investigate this and consists of three cohorts aged approximately 35 (N = 775), 55 (N = 866) and 75 years (N = 544) at the time of telomere length measurement. Four sets of measurements of SES were investigated: those collected contemporaneously with telomere length assessment, educational markers, SES in childhood and SES over the preceding twenty years. We found mixed evidence for an association between SES and telomere length. In 35-year-olds, many of the education and childhood SES measures were associated with telomere length, i.e. those in poorer circumstances had shorter telomeres, as was intergenerational social mobility, but not accumulated disadvantage. A crude estimate showed that, at the same chronological age, social renters, for example, were nine years (biologically) older than home owners. No consistent associations were apparent in those aged 55 or 75. There is evidence of an association between SES and telomere length, but only in younger adults and most strongly using education and childhood SES measures. These results may reflect that childhood is a sensitive period for telomere attrition. The cohort differences are possibly the result of survival bias suppressing the SES-telomere association; cohort effects with regard different experiences of SES; or telomere possibly being a less effective marker of biological ageing at older ages

    CP Violation and Dark Matter

    Get PDF
    A brief review is given of the effects of CP violation on the direct detection of neutralinos in dark matter detectors. We first summarize the current developments using the cancellation mechanism which allows for the existence of large CP violating phases consistent with experimental limits on the electron and on the neutron electric dipole moments in a broad class of SUSY, string and D brane models. We then discuss their effects on the scattering of neutralinos from quarks and on the event rates. It is found that while CP effects on the event rates can be enormous such effects are reduced significantly with the imposition of the EDM constraints. However, even with the inclusion of the EDM constraints the effects are still very significant and should be included in a precision prediction of event rates in any SUSY, string or D brane model.Comment: Based on an invited talk at the conference "Sources and Detection of Dark Matter in the Universe", at Marina del Rey, CA, Feb. 23-25, 2000; 12 pages, Latex including 2 figure
    corecore